UNE-EN-60068-2-1, COLD TEST

The objective of this test is determine the capacity of the electronic equipments to be storage or used under low temperatures.

For this purpose is used the test Ab (cold test for samples that do not dissipate heat with low temperature variation), recommended the standard UNE 135401-2 EX, which is found in the standard EN 60068-2-1. This standards define the equipments to use in the test and the conditioning procedures with the máximum configuration and load, and under conditions of not work, excepting in the last period of low temperature. The minimum severity of the temperature will be -10ºC. The manufacturer could opt for certify a lower temperature, between the defined standards
The minimum exposure to a lower temperature will be 16 hours, from the stabilization of the chamber.

More information in: www.dycometal.com 

CET-40/1000 - TEMPERATURE TEST CHAMBER (1000 Liters)




DYCOMETAL, company with over 25 years experience in developing simulation chambers for environmental testing, offers customers Temperature Test chambers to carry out climatic tests