The objective of this test
is determine the capacity of the electronic equipments to be storage or used
under low temperatures.
For this purpose is used the
test Ab (cold test for samples that do not dissipate heat with low temperature
variation), recommended the standard UNE 135401-2 EX, which is found in the
standard EN 60068-2-1. This standards define the equipments to use in the test
and the conditioning procedures with the máximum configuration and load, and
under conditions of not work, excepting in the last period of low temperature.
The minimum severity of the temperature will be -10ºC. The manufacturer could
opt for certify a lower temperature, between the defined standards
The minimum exposure to a
lower temperature will be 16 hours, from the stabilization of the chamber.