The objective of this test
is determine the capacity of the electronic equipments to be storage or used
under high temperatures.
For this purpose is used the
Bd test (dry heat test for samples with low variation of temperature) recommended
the standard UNE 135401-2 EX, which is found in the standard EN 60068-2-1.
The test will be done with
the equipments in their máximum configuration and load in a workspace with
enough dimensions to do tests. The minimum several of temperature will be 60ºC.
The manufacturer could opt for certify a lower temperature, between the defined
standards
The minimum exposure to a
lower temperature will be 16 hours, from the stabilization of the chamber.
More information at: www.dycometal.com
AFA-150/768 - OVEN (768 Liters) |
DYCOMETAL, company with over 25 years experience in developing
simulation chambers for environmental testing, offers customers Ovens
to carry out climatic
tests