UNE-EN-60068-2-52, Cyclical corrosion test

The purpose of this test is to determine the capacity of the equipment to be stored or used under conditions of high humidity combined with high salinity conditions.

The purpose of this test is to determine the capacity of the equipment to be stored or used under conditions of salinity, followed by high humidity and high temperature

The sample will be tested in a neutral salinity atmosphere (pH 6,5 -7,2), with a fallout rate between 1 and 2 ml/80cm2/hour, the temperature could be from +15ºC to +35ºC. After this point, the sample will be tested during 7 days at high humidity (93 %RH) and at +40ºC.




More information at: www.dycometal.com


DYCOMETAL, company with over 25 years experience in developing simulation chambers for environmental testing, offers customers Cyclical Corrosion Chambers to carry out climatic tests.