DYCOMETAL EQUIPOS DE CONTROL DE LA CALIDAD, S.L., the Trademark that has given to their products the comitment that each one of them, depending on its own characteristics, can reproduce faithfully all the environmental conditions that Nature is able to offer to obtain a better Quality of the materials.
Translate
miércoles, 27 de enero de 2016
lunes, 25 de enero de 2016
jueves, 21 de enero de 2016
GM 4465, General Motors, Humidity Test
The most manufacturers have
their own testing standards In the automobile sector. This is one example of
it, the GM 4465 standard from General Motors.
To comply this test, the
samples will be exposured to a water fog, with a fallout rate between 1 and 2
ml/80cm2/hour. The temperature of the cabinet will be +38ºC and the relative
humidty will be 100% RH, These conditions must remain constant during the cycle.
CH-2000 - Humidity Test Chamber (2000 liters) |
More information: www.dycometal.com
DYCOMETAL, company with over 25 years experience in developing
simulation chambers for environmental testing, offers customers Humidostatic
chambers (Condensation chambers) to carry this tests.
miércoles, 13 de enero de 2016
ASTM D2247, WATER-RESISTANT 100% RH
This standard is used in
order to test the water resistance of coatings using treated specimen to a high
humidity and high temperature exposure, until condensation on the elements to
be tested.
It will create an atmosphere
consisting of a heated mixture of saturated air and water vapor. The
temperature is 38°C and a relative humidity of 100%. This environment is kept
in steady state conditions until you go producing condensation in samples. You will
be subsequently evaluated the piece being tested.
More information at: www.dycometal.com
DYCOMETAL, company with over 25 years experience in developing
simulation chambers for environmental testing, offers customers Humidostatic
chambers (Condensation chambers) to carry this tests.
jueves, 7 de enero de 2016
ASTM D1735, WATER RESISTANCE
This type of test is
intended for the analysis of coatings and its resistance to corrosion from
exposure to water, at high temperatures.
The
samples will be exposed to a water fog. The temperature of the chamber is 38ºC,
and the fallout rate between 1,5 y 3 ml/80 cm2/ hora. Time of test would be
variable.
CH-2000, Humidostatic test chamber for big samples (2000 liters) |
DYCOMETAL, company with over 25 years experience in developing
simulation chambers for environmental testing, offers customers Humidostatic
chambers (Condensation chambers) to carry out climatic tests.
martes, 5 de enero de 2016
UNE-EN-60068-2-52, Cyclical corrosion test
The purpose of this test is
to determine the capacity of the equipment to be stored or used under
conditions of high humidity combined with high salinity conditions.
The purpose of this test is
to determine the capacity of the equipment to be stored or used under
conditions of salinity, followed by high humidity and high temperature
The sample will be tested in
a neutral salinity atmosphere (pH 6,5 -7,2), with a fallout rate between 1 and
2 ml/80cm2/hour, the temperature could be from +15ºC to +35ºC. After this
point, the sample will be tested during 7 days at high humidity (93 %RH) and at
+40ºC.
More information at: www.dycometal.com
DYCOMETAL, company with over 25 years experience in developing
simulation chambers for environmental testing, offers customers Cyclical
Corrosion Chambers to
carry out climatic tests.