Translate

viernes, 31 de octubre de 2014

Rain test Chamber, CLL series

Rain test is done over different components to evaluate the IP degree protection,according standard DIN 40 053, in the rain test chambers

Feature Nº.
Protection Type
Equipment
IP-X1
Vertical fall of drops of water
Drip box, gyratory platform

IP-X2
Waterfalls with a 15 degrees maximum tilt
Drip box, static platform
IP-X3
Water falls as rain
Oscillatory pipe or sprinkler head
IP-X4
Water projections
Spray with fix/swivel, gyratory platform.
IP-X5
Water jets
Spray with nozzle Ø 6.3 mm
IP-X6
Strong jets of water
Spray with nozzle 12.5 mm Ø
IP-X7
emporary immersion in water
Bath immersion


To big lights, DYCOMETAL, has developed a special equipment to do the rain test

The equipment is manufactured by a drip box (IPX1 and IPX2), two rain arcs and showers (IPX3 and IPX4). We have provided also the use of the circuits for 5 and 6 degree test.

The control of the systems comes commanded by a powerful microprocessor, which regulate wáter spray time, the measure of the wáter flow in l/min, and electrical feed to the sample by the connection box in the rotating plate.

Special Rain test chamber



DYCOMETAL, company with over 25 years experience in developing simulation chambers for environmental testing, offers customers Rain test Chambers to carry out such tests.

jueves, 6 de marzo de 2014

PV 1200, Resistance to environmental cycle test

PV 1200 describes an environmental cycle test (elevated temperature/low temperature cycle) for testing units.

The samples will be placed in the test chamber, and will be exposed to an atmosphere of 80%RH and +80ºC (80/80). These conditions will be modified along the test to -40ºC and then will be rise to room temperature. The duration of the test will be 720 minutes.


DYCOMETAL, company with over 25 years experience in developing simulation chambers for environmental testing, offers customers Climatic Chambers to carry out such tests.

Climatic Test Chamber: PV 2005 – Variant A

PV 2005 is used in automotive parts to do quality tests in order to evaluate their behavior during an accelerated climatic stress cycle.

Variant-A will be applied over the single parts, and it will be done in a climatic chamber. The duration for one cycle will be 12 hours, with temperature range between 80ºC and -35ºC, and with humidity range between 30 and 80% RH. It will exist a limitation in the water content of the air during the heating cycle.
The number of cycle depends of the specification of the product.




DYCOMETAL, company with over 25 years experience in developing simulation chambers for environmental testing, offers customers Climatic Chambers to carry out such tests.

miércoles, 8 de enero de 2014

Special Climatic Chamber for Test Bench

Climatic test reproduce the climatic conditions in temperature and humidity, to which the equipment or materials will be subjected during operation, transport or storage.

It’s necessary, do these tests in the validation plan of a new product or over its production, to evaluate equipment behavior, in its climatic use conditions, and prevent malfunctions in the market. Climatic chambers simulate humidity and temperature conditions that will affect to the product along its lifetime

Sometimes, it’s necessary to put the samples under a specific temperature and humidity conditions, during a test in a test bench. Introduce the test bench in a standard climatic chamber is complicated. For this reason, Dycometal manufactures an external conditioner system to obtain the necessary temperature and humidity conditions to do the test.




DYCOMETAL, company with over 25 years experience in developing simulation chambers for environmental testing, offers customers Special Climatic Chambers for test bench to carry out such tests.

Special Climatic Chamber to Aeronautical industry

Climatic test reproduce the climatic conditions in temperature and humidity, to which the equipment or materials will be subjected during operation, transport or storage.

It’s necessary, do these tests in the validation plan of a new product or over its production, to evaluate equipment behavior, in its climatic use conditions, and prevent malfunctions in the market. Climatic chambers simulate humidity and temperature conditions that will affect to the product along its lifetime

Sometimes, when the load conditions of the sample to be tested require of different solution like the traditional, it’s necessary redesign the chamber in order to adequate to the sample. In the case of the biggest aeronautical pieces, Dycometal has designed a special climatic chamber with vertical door aperture, for introduce the samples vertically.




DYCOMETAL, company with over 25 years experience in developing simulation chambers for environmental testing, offers customers Special Climatic Chambers to carry out such tests.

martes, 7 de enero de 2014

WALK-IN Salt Spray Chamber

One of the most important destructive agents of the nature is the corrosion, being one of the principals causes of economic lose.

All the markets: automotive, aeronautical, railway, paints or any type of metal treatment industry, have corrosion test simulation inside their quality standards. Sometimes, the samples to be tested are too big, so they need solutions with bigger volumes. In this case, we use the Walk-in Salt Spray Chambers.

The Salt Spray Corrosion Test consists of an accelerated corrosion attack by an artificial salt spray of a certain composition, in the exact conditions of temperature and pressure. To do this type of tests, it uses the salt spray chambers.

Standards like: ASTM B117, DIN 50 021 or DIN 50 017, establish a test parameters to simulate the most aggressive atmospheres.




DYCOMETAL, company with over 25 years experience in developing simulation chambers for environmental testing, offers customers WALK-IN Salt Spray Chambers to carry out such tests.

ASTM B117, Neutral Salt Spray Test NSS

ASTM B117 is used to test the corrosion resistance of metallic parts with or without coating; exposing the sample saline atmospheres and high temperature

The samples are introduced into the chamber with an acid atmosphere, pH between 6’5 to 7’2, and temperature of 35ºC. The collection rate must to be between a to 2 ml/hour. The collector will have a surface of 80 cm2  




DYCOMETAL, company with over 25 years experience in developing simulation chambers for environmental testing, offers customers Salt Spray Chambers to carry out such tests.