DYCOMETAL EQUIPOS DE CONTROL DE LA CALIDAD, S.L., the Trademark that has given to their products the comitment that each one of them, depending on its own characteristics, can reproduce faithfully all the environmental conditions that Nature is able to offer to obtain a better Quality of the materials.
Translate
viernes, 31 de julio de 2015
martes, 28 de julio de 2015
UNE-EN-60068-2-11, NEUTRAL SALT SPRAY TEST (NSS)
The purpose of this test is
to determine the capacity of the equipment to be stored or used under
conditions of high humidity combined with high salinity conditions. This test
is known like NSS test (Neutral Salt Spray test).
The sample will be tested in
a neutral salinity atmosphere (pH 6,5 -7,2), with a fallout rate between 1 and
2 ml/80cm2/hour, while the temperature of the chamber is +35ºC, the time of the test could vary.
More information: www.dycometal.com
SSC-400, SALT SPRAY CHAMBER (400 Liters) |
DYCOMETAL, company with over 25 years experience in developing
simulation chambers for environmental testing, offers customers Salt
Spray Chambers to carry out climatic
tests.
lunes, 27 de julio de 2015
UNE-EN-60068-2-30, DAMP HEAT TEST, Cyclic
The purpose of this test is
to determine the capacity of the equipment to be stored or used under
conditions of high humidity combined with cyclic variations of temperature and,
in general, with condensation to form on its surface.
To do this, use option 2 of
the test preferred UNE 135401-2 EX 1 standard, which is defined in the standard
EN 60068-2-30 Db (damp heat cyclic test) 16. This standard also defines use
test devices and procedures of preparation, recovery and measures. The test
will take place with the equipment with
its maximum settings and load and operating conditions. The minimum severity of
the test will be: temperature: 40 ° C number of cycles: 2.
The manufacturer may choose
to certify a higher severity, by selecting other values of temperature and
number of cycles among those defined by the standard.
More information at: www.dycometal.coml.com
CCK-40/1000 - CLIMATIC CHAMBER (1000 liters) |
DYCOMETAL, company with over 25 years experience in developing
simulation chambers for environmental testing, offers customers Climatic
Chambers to carry out climatic
tests.
domingo, 26 de julio de 2015
HUMID CHAMBER FOR CONDITIONING OF PLASTIC PARTS
Within the plastic industry,
polyamide parts must be upgraded to high temperatures and humidity for
dimensional stability and impact resistance.
For a homogeneous
conditioning, humidity chambers, have a uniform airflow, which guarantees that
all parts have the same conditions of temperature and humidity. These cameras
tend to be built in stainless steel internally and its internal dimensions tend
to be high-volume to put up the largest number of samples simultaneously.
DYCOMETAL, company with over 25 years experience in developing
simulation chambers for environmental testing, offers customers High
Humidity Test Chambers to
carry out climatic tests.
viernes, 24 de julio de 2015
Accelerated aging in plastic parts: Rain
Currently, plastic parts
make up most of the things that surround us: cars, computers, etc. These pieces
have been of different quality controls other than the metallic materials.
There are many types of plastic, but a difference among them is the time of
degradation to which they are subject from its manufacture.
Rain is another factor
affecting the degradation of plastic parts. The most prominent trials are those
during which parts are wet (dew, rain or moisture after rain periods). Water
can contribute to the degradation of plastics.
More details at: www.dycometal.com
CCL-2900e- RAIN TEST CHAMBER, Special desig for Automotive parts (2900 liters) |
DYCOMETAL, company with over 25 years experience in developing
simulation chambers for environmental testing, offers customers Rain test
Chambers to carry out climatic
tests
martes, 21 de julio de 2015
Accelerated aging in plastic parts: Temperature
Currently, plastic parts
make up most of the things that surround us: cars, computers, etc. These pieces
have been of different quality controls other than the metallic materials.
There are many types of plastic, but a difference among them is the time of degradation
to which they are subject from its manufacture.
Temperature is one of the
factors affecting the degradation, all chemical reaction is accelerated with
increasing temperature, and plastics are no exception, so increasing
temperature on plastic parts we increase the degradation of the same. Plastics
have a low thermal conductivity, so that if a piece of plastic is exposed to
the Sun, its temperature will increase much more, and can reach temperatures
well above room temperature..
More information at: www.dycometal.com
AFA-150/5120 - FORCED AIR HEATING OVEN (5120 Liters) |
DYCOMETAL, company with over 25 years experience in developing
simulation chambers for environmental testing, offers customers Ovens
to carry out climatic
tests
Aging accelerated in plastic parts: RADIATION
Currently, plastic parts
make up most of the things that surround us: cars, computers, etc. These pieces
have been of different quality controls, non-metallic materials. There are many
types of plastic, but a difference among them is the time of degradation to
which they are subject from its manufacture.
One of the factors affecting
the degradation is the solar radiation: ultraviolet (UV), visible and infrared
(IR); still it UV which most affects the molecular structure of the plastic,
accelerating the process of degradation. UV light, accelerated aging chambers
allow the simulation of the conditions that the plastic will face during its
life, at a certain temperature and under conditions of UV radiation.
More information at: www.dycometal.com
CCK-40/300 - CLIMATIC CHAMBER WITH SOLAR SIMULATION (300 Liters) |
DYCOMETAL, company with over 25 years experience in developing
simulation chambers for environmental testing, offers customers Chambers
to carry out climatic
tests
lunes, 20 de julio de 2015
UNE-EN-60068-2-2, Driy Heat Test – Ovens
The objective of this test
is determine the capacity of the electronic equipments to be storage or used
under high temperatures.
For this purpose is used the
Bd test (dry heat test for samples with low variation of temperature) recommended
the standard UNE 135401-2 EX, which is found in the standard EN 60068-2-1.
The test will be done with
the equipments in their máximum configuration and load in a workspace with
enough dimensions to do tests. The minimum several of temperature will be 60ºC.
The manufacturer could opt for certify a lower temperature, between the defined
standards
The minimum exposure to a
lower temperature will be 16 hours, from the stabilization of the chamber.
More information at: www.dycometal.com
AFA-150/768 - OVEN (768 Liters) |
DYCOMETAL, company with over 25 years experience in developing
simulation chambers for environmental testing, offers customers Ovens
to carry out climatic
tests
viernes, 12 de junio de 2015
UNE-EN-60068-2-1, COLD TEST
The objective of this test
is determine the capacity of the electronic equipments to be storage or used
under low temperatures.
For this purpose is used the
test Ab (cold test for samples that do not dissipate heat with low temperature
variation), recommended the standard UNE 135401-2 EX, which is found in the
standard EN 60068-2-1. This standards define the equipments to use in the test
and the conditioning procedures with the máximum configuration and load, and
under conditions of not work, excepting in the last period of low temperature.
The minimum severity of the temperature will be -10ºC. The manufacturer could
opt for certify a lower temperature, between the defined standards
The minimum exposure to a
lower temperature will be 16 hours, from the stabilization of the chamber.
More information in: www.dycometal.com
CET-40/1000 - TEMPERATURE TEST CHAMBER (1000 Liters) |
DYCOMETAL, company with over 25 years experience in developing
simulation chambers for environmental testing, offers customers Temperature Test chambers to carry out climatic tests
miércoles, 10 de junio de 2015
DYCOMETAL BIO-SCIENCE CHAMBERS
In the R&D market, the
climatic chamber has an important application inside of the botanic sector,
thanks to the Plants Growth Chambers and seeds germination chamber.
These chambers present the
optimal conditions in humidity, temperature and solar radiation, to generate
the optimal atmosphere for the growing of the plants. It’s possible to control
other variables like gases (CO2, CO, etc).
The dimensions of the
chamber can change from the smaller laboratory until the walk-in chambers,
where is possible to do extensive cultives.
More information in: www.dycometal.com
DYCOMETAL, company with over 25 years experience in developing
simulation chambers for environmental testing, offers customers PLANTS GROWTH CHAMBERS AND SEEDS GERMINATION CHAMBERS to carry out such tests.
miércoles, 3 de junio de 2015
NEW YOUTUBE CHANNEL
Dear customers and Friends,
From DYCOMETAL, we want to approach our products to all , for this reason we have opened a new youtube channel where we will put the different products from DYCOMETAL.
You can see the new videos from our products in this link:
We will upload all the special products and standard products. We hope that you will enjoy it
Remember that you have more information in our website: www.dycometal.com
viernes, 27 de marzo de 2015
viernes, 9 de enero de 2015
MIL-STD-810, SALT SPRAY TEST
The objective of the
salt spray test is to determine the effectiveness of protective coatings and
surface finishes, and is used to determine the effects of salt deposicones in
electrical and physical materials.
The samples will be placed in the chamber, and
they will be exposed to an indirect salt spray with neutral pH (beween 6.5 to
7.2). the concentration must to be 5±1%, and the falla-out rate must to be
between 0.5 and 3 ml/80cm2/hour. The temperature of the test will be +35ºC.
After 48 hours of test, the samples will be dried another 48 hours.
SSC-400, SALT SPRAY CHAMBER (400 liters) |
DYCOMETAL, company with over 25 years experience in developing
simulation chambers for environmental testing, offers customers SALT SPRAY CHAMBERS to
carry out climatic tests.
jueves, 8 de enero de 2015
MIL-STD-810 Method 506.4, RAIN TESTRAIN TEST CHAMBER
The Rain tightness tests are performed to different components to
evaluate the IP degree of protection, in the Rain test Chambers.
MIL-STD-810 test method in its
method 506.4, to evaluate any element to be exposed to rain, spraying or dripping
water during storage or transport operation.
Its goal is to determine:
- The
effectiveness of covers, housings and seals to prevent water penetration into
the material
-
The
ability of the material to satisfy the requirements before and after exposure
to water
-
Determine
whether there is any physical deterioration of the material caused by rain
- The
effectiveness of any system of water extraction
-
The
effectiveness of protection offered by the material.
DYCOMETAL, company with over 25 years experience in developing
simulation chambers for environmental testing, offers customers RAIN TEST CHAMBERS CHAMBERS to
carry out climatic tests.
miércoles, 7 de enero de 2015
MIL-STD-810 Method 510.4, Dust and Sand Test
The dust tightness tests are performed to different components to
evaluate the IP degree of protection, in the Dust Chambers.
MIL-STD-810 test
method in its method 510.4, set the test parameters to assess any mechanical,
optical, electrical, electronic, electromechanical and electrochemical element
which may be exposed during use or storage in dusty atmospheres or sand.
This standard
establishes two parts:
• Small
particles of dust (˂149 microns) to assess the system's resistance to dust
against obstructions, cracks, etc.
• Blowing
sand (150-850 microns) to evaluate the systems and determine whether the
material can be stored and operated under conditions of blowing sand without